Comparison

Secretin (SCT) BioAssay™ ELISA Kit (Mouse)

Item no. USB-027984-96Tests
Manufacturer United States Biological
Amount 96 tests
Quantity options 96 tests 96 tests
Specific against other
Shipping condition Cool pack
Available
Manufacturer - Category
Kits and Assays / Kits-ELISA, BioAssay™
Shipping Temperature
Blue Ice
Storage Conditions
4°C/-20°C
EU Commodity Code
38220000
Description
Secretin (SCT) BioAssay™ ELISA Kit (Mouse) is a competitive inhibition immunoassay for in vitro quantitative measurement of SCT in mouse serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Detection Range:
12.35-1000pg/ml

Sensitivity:
4.95pg/ml

Intra-Assay CV:
<10%

Inter-Assay CV:
<12%

Kit Components:
*027984A: Microtiter Plate, 96 wells, Pre-coated, ready to use
*027984B: Standard, 2x1vial
027984C: Standard Diluent, 1x20ml
*027984D: Detection Reagent A (green), 1x120ul
*027984E: Detection Reagent B (red), 1x120ul
027984F: Assay Diluent A, 1x12ml
027984G: Assay Diluent B, 1x12ml
027984H: TMB Substrate, 1x9ml
027984K: Stop Solution, 1x6ml
027984L: Wash Buffer, 30X, 1x20ml

Precaution:
The Stop Solution (027984K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

Storage and Stability:
Store *027984A, *027984B, *027984D and *027984E at -20°C. Store all the other components at 4°C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.

Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50ul standard or sample to each well.
3. Add 50ul prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C.
4. Aspirate and wash 3 times.
5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37°C.
6. Aspirate and wash 5 times.
7. Add 90ul Substrate Solution. Incubate 15-25 minutes at 37°C.
8. Add 50ul Stop Solution. Read at 450nm immediately.
Shelf Life
6months

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 tests
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close