Comparison

CLIA Kit for Ovalbumin (OVA)

Item no. CCB459Ge-96T
Manufacturer Cloud-Clone
Amount 96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against other
Sensitivity The minimum detectable dose of this kit is typically less than </td></tr><tr><th>Sample type</th><td colspan="7">Tissue homogenates, cell lysates and other biological fluids</td></tr><tr><th>Assay length</th><td colspan="7">2h</td></tr><tr><th>Method</th>
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Specificity Pan-species (General)
Manufacturer - Category
CLIA Kit
Sample type
Tissue homogenates, cell lysates and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity
This assay has high sensitivity and excellent specificity for detection of Ovalbumin (OVA).
No significant cross-reactivity or interference between Ovalbumin (OVA) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ovalbumin (OVA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ovalbumin (OVA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50μL standard or sample to each well.
        And then add 50μL prepared Detection Reagent A immediately.
        Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100μL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Test principle
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Ovalbumin (OVA). A competitive inhibition reaction is launched between biotin labeled Ovalbumin (OVA) and unlabeled Ovalbumin (OVA) (Standards or samples) with the pre-coated antibody specific to Ovalbumin (OVA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Ovalbumin (OVA) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Ovalbumin (OVA) level in the sample or standard.
Manufacturer - Research Area
Infection immunity; Immune molecule; Hematology

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close