Comparison

ELISA Kit for Dihydrotestosterone (DHT)

Item no. CEA443Ge-5x96T
Manufacturer Cloud-Clone
Amount 5x96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against other
Sensitivity The minimum detectable dose of this kit is typically less than 10.7pg/mL
Citations Herbicide Metolachlor Causes Changes in Reproductive Endocrinology of Male Wistar Rats
Metabolic Changes and Hormonal Disturbances in Polycystic Ovarian Syndrome Rats and the Amelioration Effects of Metformin and/or Cinnamon Extraction
Treatment of benign prostatic hyperplasia with Croton membranaceus in an experimental animal model
Oral administration of low-dose bisphenol A promotes proliferation of ventral prostate and upregulates prostaglandin D2
Testosterone Replacement Modulates Cardiac Metabolic Remodeling after Myocardial Infarction by Upregulating PPARα
Dihydrotestosterone Treatment Accelerates Autograft Reversal Sciatic Nerve Regeneration in Rats
Uterine progesterone signaling is a target for metformin therapy in polycystic ovary syndrome
Dihydrotestosterone synthesis in the sheep corpus luteum and its potential mechanism in luteal regression
Syce1 and Syce3 regulate testosterone and dihydrotestosterone synthesis via steroidogenic pathways in mouse Sertoli and Leydig cells
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias 5α-DHT,5α-Dihydrotestosterone,Androstanolone,Stanolone
Available
Specificity Pan-species (General)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Manufacturer - Species
Pan-species (General)
Sample type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity

This assay has high sensitivity and excellent specificity for detection of Dihydrotestosterone (DHT).

No significant cross-reactivity or interference between Dihydrotestosterone (DHT) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Dihydrotestosterone (DHT) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Dihydrotestosterone (DHT) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 50uL standard or sample to each well.

        And then add 50uL prepared Detection Reagent A immediately.

        Shake and mix. Incubate 1 hour at 37° C;

3. Aspirate and wash 3 times;

4. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

5. Aspirate and wash 5 times;

6. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

7. Add 50uL Stop Solution. Read at 450 nm immediately.
Test principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Dihydrotestosterone (DHT) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Dihydrotestosterone (DHT) and unlabeled Dihydrotestosterone (DHT) (Standards or samples) with the pre-coated antibody specific to Dihydrotestosterone (DHT). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Dihydrotestosterone (DHT) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Dihydrotestosterone (DHT) in the sample.
Manufacturer - Research Area
Endocrinology; Reproductive science; Hormone metabolism;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 5x96 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close