Comparison

ELISA Kit for Folic Acid (FA)

Item no. CEA610Ge-10x96T
Manufacturer Cloud-Clone
Amount 10x96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against other
Sensitivity The minimum detectable dose of this kit is typically less than 285.77pg/mL
Citations Vitamin Status and the Development of Postoperative Cognitive Decline in Elderly Surgical Oncologic Patients.Development of Orally Applicable, Combinatorial Drug–Loaded Nanoparticles for the Treatment of FibrosarcomaRole of folic acid deficiency as a possible risk factor for erectile dysfunctionLow serum folic acid can be a potential independent risk factor for erectile dysfunction: a prospective case–control studyEnhanced cellular uptake, transport and oral bioavailability of optimized folic acid-loaded chitosan nanoparticlesFolate, Vitamin B12, and Homocysteine Levels in Women With Neural Tube Defect-Affected Pregnancy in Addis Ababa, Ethiopia
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias VB9,Vitamin B9,Folacin,Folate,V,Itamin M,Vitamin M,Vitamin Bc,Pteroyl-L-Glutamic Acid,Pteroyl-L-Glutamate
Available
Specificity Pan-species (General)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Manufacturer - Species
Pan-species (General)
Sample type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity

This assay has high sensitivity and excellent specificity for detection of Folic Acid (FA).

No significant cross-reactivity or interference between Folic Acid (FA) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Folic Acid (FA) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Folic Acid (FA) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 50uL standard or sample to each well.

        And then add 50uL prepared Detection Reagent A immediately.

        Shake and mix. Incubate 1 hour at 37° C;

3. Aspirate and wash 3 times;

4. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

5. Aspirate and wash 5 times;

6. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

7. Add 50uL Stop Solution. Read at 450 nm immediately.
Test principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Folic Acid (FA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Folic Acid (FA) and unlabeled Folic Acid (FA) (Standards or samples) with the pre-coated antibody specific to Folic Acid (FA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Folic Acid (FA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Folic Acid (FA) in the sample.
Manufacturer - Research Area
Hematology; Reproductive science; Nutrition metabolism;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.