ELISA Kit for Ghrelin (GHRL)

Item no. CEA991Ra-48T
Manufacturer Cloud-Clone
Amount 48 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against Rat (Rattus norvegicus)
Sensitivity The minimum detectable dose of this kit is typically less than 52.3pg/mL
Citations Effect of Sleeve Gastrectomy Plus Side-to-Side Jejunoileal Anastomosis for Type 2 Diabetes Control in an Obese Rat ModelEffects of sleeve gastrectomy with jejuno-jejunal or jejuno-ileal loop onglycolipid metabolism in diabetic rats.EFFECT OF Garcinia cambogia EXTRACT ON SERUM LEPTIN, GHRELIN, ADIPONECTIN AND INSULIN LEVELS AND BODY WEIGHTS IN RATS FED WITH HIGH …Omega-3 offers better hypothalamus protection by decreasing POMC expression and elevating ghrelin hormone: a prospective trial to overcome methotrexate …Physiological and Histopathological Effects of Electroporation Pulse on Stomach of RatsEffect of Sleeve Gastrectomy, Roux-En-Y Gastric Bypass, and Ileal Transposition on Myocardial Ischaemia–Reperfusion Injury in Non-Obese Non-Diabetic RatsThe microbiota-gut-kidney axis mediates host osmoregulation in a small desert mammal
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias MTLRP,Growth Hormone-Releasing Peptide
Available
Specificity Rattus norvegicus (Rat)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity

This assay has high sensitivity and excellent specificity for detection of Ghrelin (GHRL).

No significant cross-reactivity or interference between Ghrelin (GHRL) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ghrelin (GHRL) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ghrelin (GHRL) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 50uL standard or sample to each well.

        And then add 50uL prepared Detection Reagent A immediately.

        Shake and mix. Incubate 1 hour at 37° C;

3. Aspirate and wash 3 times;

4. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

5. Aspirate and wash 5 times;

6. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

7. Add 50uL Stop Solution. Read at 450 nm immediately.
Test principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Ghrelin (GHRL) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Ghrelin (GHRL) and unlabeled Ghrelin (GHRL) (Standards or samples) with the pre-coated antibody specific to Ghrelin (GHRL). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Ghrelin (GHRL) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Ghrelin (GHRL) in the sample.
Manufacturer - Research Area
Signal transduction; Metabolic pathway; Endocrinology; Gastroenterology; Hormone metabolism;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 48 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close