Comparison

FLRT3 ELISA Kit (Human)

Item no. OKCD00701
Manufacturer AVIVA Systems Biology
Amount 96 Wells
Category
Type Elisa-Kit
Applications ELISA
Specific against Human (Homo sapiens)
Sensitivity < 0.57 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias fibronectin-like domain-containing leucine-rich transmembrane protein 3;HH21;leucine-rich repeat transmembrane protein FLRT3.
Shipping Condition Cool pack
Available
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
FLRT3
Gene Fullname
fibronectin leucine rich transmembrane protein 3
Protein size
649
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Functions in cell-cell adhesion, cell migration and axon guidance, exerting an attractive or repulsive role depending on its interaction partners. Plays a role in the spatial organization of brain neurons. Plays a role in vascular development in the retina (By similarity). Plays a role in cell-cell adhesion via its interaction with ADGRL3 and probably also other latrophilins that are expressed at the surface of adjacent cells (PubMed:26235030). Interaction with the intracellular domain of ROBO1 mediates axon attraction towards cells expressing NTN1. Mediates axon growth cone collapse and plays a repulsive role in neuron guidance via its interaction with UNC5B, and possibly also other UNC-5 family members (By similarity). Promotes neurite outgrowth (in vitro) (PubMed:14706654). Mediates cell-cell contacts that promote an increase both in neurite number and in neurite length. Plays a role in the regulation of the density of glutamaergic synapses. Plays a role in fibroblast growth factor-mediated signaling cascades. Required for normal morphogenesis during embryonic development, but not for normal embryonic patterning. Required for normal ventral closure, headfold fusion and definitive endoderm migration during embryonic development. Required for the formation of a normal basement membrane and the maintenance of a normal anterior visceral endoderm during embryonic development (By similarity).
Nucleotide accession_num
NM_013281.3
Protein accession_num
NP_037413
Protein name
Leucine-rich repeat transmembrane protein FLRT3
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3).No significant cross-reactivity or interference between Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich Immunoassay
Kit Components
Component: Amount
Anti-FLRT3 Microplate: 96 Wells (12 x 8 Well Strips)
FLRT3 Lyophilized Standard: 2 x 100 ng
100X Biotinylated FLRT3 Detector Antibody: 120 uL
Avidin/HRP Conjugate: 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
TMB Substrate: 1 x 9 mL
Stop Solution: 1 x 6 mL
Kit detection
Colorimetric
Kit duration
3h
Kit linearity
Sample - 1:2 Dilution - 1:4 Dilution - 1:8 Dilution - 1:16 Dilution
- 91-103% - 92-101% - 80-89% - 97-104%
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery Range (%) - Average (%)
- 97-105 - 101
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibronectin Leucine Rich Transmembrane Protein 3 (FLRT3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates, cell lysates and other biological fluids.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 Wells
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close