Comparison

ELISA Kit for Leptin (LEP)

Item no. SEA084Bo-10x96T
Manufacturer Cloud-Clone
Amount 10x96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against Cow (Bos taurus), Cattle (Bovine)
Sensitivity The minimum detectable dose of this kit is typically less than 0.060ng/mL
Citations Ovarian, metabolic and endocrine indexes in dairy cows with different body condition scores
EFFECT OF LEPTIN GENE ON SERUM LEPTIN CONCENTRATION AND BEEF QUALITY IN CZECH FLECKVIEH BULLS
Estimation of the intramuscular fat content of m. longissimus thoracis in crossbred beef cattle based on live animal measurements.
Correlation of Leptin, Insulin and Glucose During Late Gestation and Early Lactation in Murrah Buffaloes
Metabolomics for the effect of biotin and nicotinamide on transition dairy cows
THE INDIAN JOURNAL OF VETERINARY SCIENCES & BIOTECHNOLOGY
Peripheral concentrations of metabolic and inflammatory indicators during transition period and their relationship with postpartum clinical endometritis in dairy …
Comparative study on genital status, energy balance and mineral content of swamp buffalo (Luit) heifers and cows under organized system of rearing in Assam?¡­
Dairy Cattle Physiology Division ICAR-National Dairy Research Institute, Karnal-132001, Haryana, India Corresponding Authors Email ID: menalsh08vets …
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias OB,OBS,Obesity Homolog,Obesity Factor,Obese Protein
Available
Specificity Bos taurus; Bovine (Cattle)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Leptin (LEP).

No significant cross-reactivity or interference between Leptin (LEP) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leptin (LEP) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leptin (LEP) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leptin (LEP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leptin (LEP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leptin (LEP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leptin (LEP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Metabolic pathway; Endocrinology; Cardiovascular biology;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.