Comparison

ELISA Kit for Leptin (LEP)

Item no. SEA084Hu-48T
Manufacturer Cloud-Clone
Amount 48 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.058ng/mL
Citations Effect of extended photoperiod during winter on growth and onset of puberty in Murrah buffalo heifers
The Changes of Serum Leptin and Kisspeptin Levels in Chinese Children and Adolescents in Different Pubertal Stages
Estimation of the intramuscular fat content of m. longissimus thoracis in crossbred beef cattle based on live animal measurements.
Circulating and Adipose Tissue mRNA Levels of Zinc-α2-Glycoprotein, Leptin, High-Molecular-Weight Adiponectin, and Tumor Necrosis Factor-Alpha in …
Leptin Expression and Gene Methylation Patterns in Alcohol-Dependent Patients with Ethyltoxic Cirrhosis—Normalization After Liver Transplantation and Implications …
Combinational Effect of Pine Needle Polysaccharide and Kudzu Flavonoids on Cell Differentiation and Fat Metabolism in 3T3-L1 Cells
Betahistine effects on weight-related measures in patients treated with antipsychotic medications: a double-blind placebo-controlled study
Effect of fermented food consumption on biochemical parameters and adipokines levels
Cardiotrophin-1 and leptin as cardiovascular risk markers in male patients with obstructive sleep apnea syndrome
Osteoprotegerin Levels among Saudi Cardiovascular Patients.
Expression of adipokines and their receptors in adipose tissue of women with class 3 obesity with or without hypertension
Associations of apelin, leptin, irisin, ghrelin, insulin, glucose levels, and lipid parameters with physical activity during eight weeks of regular exercise training
High-dose Glycerol Monolaurate Up-Regulated Beneficial Indigenous Microbiota without Inducing Metabolic Dysfunction and Systemic Inflammation: New Insights …
Serum Asprosin Concentrations Are Increased and Associated with Insulin Resistance in Children with Obesity
Salivary Leptin and Chemerin
a novel way of gestational diabetes screening
Copeptin and Nesfatin-1 Are Interrelated Biomarkers with Roles in the Pathogenesis of Insulin Resistance in Chinese Children with Obesity
C-Peptide and leptin system in dichorionic, small and appropriate for gestational age twins—possible link to metabolic programming?
Ameliorative Effect of Ananas comosus on Cobalt Chloride-Induced Hypoxia in Caco2 cells via HIF-1α, GLUT 1, VEGF, ANG and FGF
СОСТОЯНИЕ МЕЛАТОНИН-АССОЦИИРОВАННОЙ ГОРМОНАЛЬНОЙ СИСТЕМЫ У ДЕТЕЙ С ИЗБЫТОЧНОЙ МАССОЙ ТЕЛА
Serum leptin and body mass index in a sample of Egyptian multiple sclerosis patients
Altered Serum Marker of Adipokines Profile in Breast Cancer Women
The Association of Pre-Pregnancy BMI On Leptin, Ghrelin, Adiponectin, and IGF-1 In Breast Milk, A Case Control Study
Maternal and fetal serum leptin levels and their association with maternal and fetal variables and labor: A cross-sectional study
GP73 is a TBC-domain Rab GTPase-activating protein contributing to the pathogenesis of non-alcoholic fatty liver disease without obesity
High Circulating Fibroblast Growth Factor-21 Levels as a Prognostic Marker in Fatty Pancreas Patients
SARS-CoV2 Induced Biochemical Mechanisms in Liver Damage and Intestinal Lesions.
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias OB,OBS,Obesity Homolog,Obesity Factor,Obese Protein
Available
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
serum, plasma, saliva, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Leptin (LEP).

No significant cross-reactivity or interference between Leptin (LEP) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leptin (LEP) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leptin (LEP) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leptin (LEP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leptin (LEP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leptin (LEP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leptin (LEP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Metabolic pathway; Endocrinology; Cardiovascular biology;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 48 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close