Comparison

ELISA Kit for Versican (VCAN)

Item no. SEB817Hu-96T
Manufacturer Cloud-Clone
Amount 96 Tests
Quantity options 10x96 Tests 24 Tests 48 Tests 5x96 Tests 96 Tests
Category
Type Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.29ng/mL
Citations Tumor-Produced Versican V1 Enhances hCAP18/LL-37 Expression in Macrophages through Activation of TLR2 and Vitamin D3 Signaling to Promote Ovarian Cancer Progression In VitroVersican and its associated molecules: Potential diagnostic markers for multiple myelomaClinical significance of circulatory microRNA-203 in serum as novel potential diagnostic marker for multiple myelomaTargeting of stromal versican by miR-144/199 inhibits multiple myeloma by downregulating FAK/STAT3 signalingmiR-124-3p and miR-181a-5p Mediate AT1-Receptor Autoantibody Induced Fetal Rat Cardiac Remodeling via Increased VCAN Expression
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias CSPG2,VS,ERVR,PG-M,WGN1,Chondroitin Sulfate Proteoglycan 2,Chondroitin sulfate proteoglycan core protein 2,Glial hyaluronate-binding,Large fibroblast proteoglycan
Available
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
serum, plasma, tissue homogenates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Versican (VCAN).

No significant cross-reactivity or interference between Versican (VCAN) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Versican (VCAN) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Versican (VCAN) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Versican (VCAN). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Versican (VCAN). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Versican (VCAN), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Versican (VCAN) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Developmental science; Bone metabolism;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 Tests
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close