Comparison

ELISA Kit for Catalase (CAT)

Item no. SEC418Hu-24T
Manufacturer Cloud-Clone
Amount 24 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.121ng/mL
Citations Proteomic Analysis of Polymorphonuclear Neutrophils Identifies Catalase as a Novel Biomarker of Abdominal Aortic Aneurysm
Iodinated contrast media can induce long-lasting oxidative stress in hemodialysis patients.
过氧化氢酶基因 389C>T多态位点在重庆汉族人群中的分布及其与噪音性耳聋的关联研究
Genetic polymorphisms (Pro197Leu of Gpx1, +35A/C of SOD1,
Impact of morbid obesity and bariatric surgery on antioxidant/oxidant balance of the unstimulated and stimulated human saliva
КЛИНИЧЕСКОЕ ЗНАЧЕНИЕ ФАКТОРОВ КЛЕТОЧНОЙРЕГУЛЯЦИИ И ФЕРМЕНТОВ АНТИОКСИДАНТНОЙ СИСТЕМЫУ ПАЦИЕНТОК РЕПРОДУКТИВНОГО ВОЗРАСТА С НАРУЖНЫМГЕНИТАЛЬНЫМ ЭНДОМЕТРИ
Comparison of Extracellular and Intracellular Blood Compartments Highlights Redox Alterations in Alzheimer's and Mild Cognitive Impairment Patients.
Effect of Indole-3-carbinol and/or Metformin on Female Patients with Ulcerative Colitis (Premalignant Condition): Role of Oxidative Stress, Apoptosis and Proinflammatory Cytokines
Orthodontic treatment modifies the oxidant-antioxidant balance in saliva of clinically healthy subjects.
Laminarin protects against hydrogen peroxide-induced oxidative damage in MRC-5 cells possibly via regulating NRF2
Evaluation of ADMA, carbonyl groups, CAT and NKA in depressed patients with and without posttraumatic stress disorder.
Biochemical and molecular alterations in freshwater mollusks as biomarkers for petroleum product, domestic heating oil
Multi-biomarker responses after exposure to organophosphates chlorpyrifos in the freshwater mussels and snails
Cholecystectomy Patients with High Plasma Level of Catalase Have Significantly Lower Analgesia Requirement: A Prospective Study of Two Different …
Plasma Catalase in Relation to Pain Following Midline Laparotomy: A Prospective Study of Patients with Benign Diseases and Patients with Cancer
Nitrotyrosine (NT), a Nitrosative Stress Biomarker, Plasma Concentrations in Gallstone Disease and Cancer Patients
Rectus Sheath Block (RSB) Analgesia Could Enhance Significantly the Patient Satisfaction Following Midline Laparotomy in Benign Disease and in Cancer: A …
MicroRNA‑21 contributes to the puerarin‑induced cardioprotection via suppression of apoptosis and oxidative stress in a cell model of ischemia/reperfusion injury
The Rectus Sheath Block (RSB) Analgesia Following Laparotomy Could Affect Malonidialdehyde (MDA) Concentrations in Benign Disease and Cancer
In Vitro Cell Culture Study of Anticholesterol and Antioxidant Activities of Myrmecodia platytyrae (MyP) Extract in WRL-68 Cells
Lutein reverses hyperglycemia-mediated blockage of Nrf2 translocation by modulating the activation of intracellular protein kinases in retinal pigment epithelial (ARPE …
Plasma catalase (CAT) levels in gallstone disease: Cholecystectomy patients with high plasma levels of CAT have significantly lower number of analgesic …
Associations of Antioxidant Enzymes with the Concentration of Fatty Acids in the Blood of Men with Coronary Artery Atherosclerosis
Plasma Concentration of the Lipid Peroxidation (LP) Biomarker 4-Ηydroxynonenal (4-HNE) in Benign and Cancer Patients
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Catalase (CAT).

No significant cross-reactivity or interference between Catalase (CAT) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Catalase (CAT) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Catalase (CAT) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Catalase (CAT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Catalase (CAT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Catalase (CAT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Catalase (CAT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Enzyme & Kinase; Metabolic pathway; Hepatology

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 24 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close