ELISA Kit for Klotho (KL)

Item no. SEH757Hu-24T
Manufacturer Cloud-Clone
Amount 24 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.055ng/mL
Citations High phosphate feeding induced arterial medial calcification in uremic rats: Roles of Lanthanum carbonate on protecting vasculature
Les biomarqueurs des calcifications vasculaires
Effect of secondary hyperparathyroidism serum on endothelial cells and intervention with Klotho
Human Preosteoblastic Cell Culture from a Patient with Severe Tumoral Calcinosis-Hyperphosphatemia Due to a NewGALNT3
Soluble Klotho protein as a novel serum biomarker in patients with acromegaly
Is there a role for newer biomarkers in chronic kidney disease-mineral and bone disorder management?
Clinical implication of alterations in serum Klotho levels in patients with type 2 diabetes mellitus and its associated complications
The role of klotho in chronic kidney disease
Effects of salt intervention on serum levels of Klotho influenced by salt sensitivity
Increased Plasma Level of Longevity Protein Klotho as a Potential Indicator of Cognitive Function Preservation in Patients With Schizophrenia
Investigation of the Role of Induced Overexpression of the Isolated Secreted Klotho on the A-172 Human Glioblastoma Cells
Expression of Klotho in Follicles of Patients With Polycystic Ovary Syndrome and Its Clinical Significance
Klotho is a prognostic indicator of oocytes qualities in polycystic ovary syndrome
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias KLa; Klotho Alpha
Available
Specificity Homo sapiens (Human)
Quantity options
Detection range
15.6-1, 000pg/mL
Organism species
Homo sapiens (Human)
Sensitivity
The minimum detectable dose of this kit is typically less than 6.0pg/mL
Sample type
Serum, plasma, tissue homogenates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Klotho (KL).
No significant cross-reactivity or interference between Klotho (KL) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Klotho (KL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Klotho (KL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µ L standard or sample to each well. Incubate 2 hours at 37° C;
3. Aspirate and add 100µ L prepared Detection Reagent A. Incubate 1 hour at 37° C;
4. Aspirate and wash 3 times;
5. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C;
6. Aspirate and wash 5 times;
7. Add 90µ L Substrate Solution. Incubate 10-20 minutes at 37° C;
8. Add 50µ L Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Klotho (KL). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Klotho (KL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Klotho (KL), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Klotho (KL) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area
Metabolic pathway;
Reference

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 24 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close