Comparison

Angiotensin II ELISA Kit

Item no. EIA-ANGII-1
Manufacturer Raybiotech
Amount 1 Plate Kit
Quantity options 1 Plate Kit 2 Plate Kit 5 Plate Kit
Category
Type Elisa-Kit
Specific against Human (Homo sapiens), Mouse (Murine, Mus musculus), Rat (Rattus norvegicus)
Host Hamster - Armenian
Sensitivity 0.3 pg/ml
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Similar products Angiotensinogen, Angiotensin II
Shipping Condition Cool pack
Available
Specificity This kit can theoretically detect all active angiotensins, including ANGI, ANGII, ANGIII and ANGIV as well as inactive angiotensinogen.Cross Reactivity: This EIA kit shows no cross-reactivity with any of the cytokines tested: Ghrelin, Nesfatin, NPY and AP
Manufacturer - Category
ELISA Kits|Competitive ELISA (EIA)
Shipping Temperature
Blue ice
Storage Conditions
-20°C
Compatible Sample Types
Cell Culture Supernatants
Serum
Design Principle
Competition-based
Method of Detection
Colorimetric
Quantitative/Semi-Quantitative
Quantitative
Solid Support
96-well Microplate
Gene Symbols
AGTSERPINA8
Kit Components
Pre-Coated 96-well Strip Microplate
Wash Buffer
Standard Peptide
Assay Diluent(s)
Biotinylated Peptide
HRP-Streptavidin
TMB One-Step Substrate
Stop Solution
Assay Diagram
Positive Control Sample
Capture Antibody
User Manual
Other Materials Required
Distilled or deionized water
Precision pipettes to deliver 2 µl to 1 ml volumes
Adjustable 1-25 ml pipettes for reagent preparation 100 ml and 1 liter graduated cylinders
Tubes to prepare standard and sample dilutions
Orbital shaker
Aluminum foil
Saran Wrap
Absorbent paper
Microplate reader capable of measuring absorbance at 450nm
Sigma
Plot software (or other software that can perform four-parameter logistic regression models)
Protocol Outline
Prepare all reagents, samples and standards as instructed.
Add 100 µl detection antibody to each well.
Incubate 1.5 h at RT or O/N at 4°C.
Add 100 µl standard or sample to each well.
Incubate 2.5 h at RT.
Add 100 µl prepared streptavidin solution.
Incubate 45 min at RT.
Add 100 µl TMB One-Step Substrate Reagent to each well.
Incubate 30 min at RT.
Add 50 µl Stop Solution to each well.
Read plate at 450 nm immediately.
Product Features
Strip plates and additional reagents allow for use in multiple experiments
Quantitative protein detection
Establishes normal range
The best products for confirmation of antibody array data
Protein Name & Synonyms
Angiotensinogen (Serpin A8) [Cleaved into: Angiotensin-1 (Angiotensin 1-10) (Angiotensin I) (Ang I) Angiotensin-2 (Angiotensin 1-8) (Angiotensin II) (Ang II) Angiotensin-3 (Angiotensin 2-8) (Angiotensin III) (Ang III) (Des-Asp[1]-angiotensin II) Angiotensin-4 (Angiotensin 3-8) (Angiotensin IV) (Ang IV) Angiotensin 1-9 Angiotensin 1-7 Angiotensin 1-5 Angiotensin 1-4]
UNSPSC Code
41116158
Manufacturer - Specificity
This kit can theoretically detect all active angiotensins, including ANGI, ANGII, ANGIII and ANGIV as well as inactive angiotensinogen.Cross Reactivity: This EIA kit shows no cross-reactivity with any of the cytokines tested: Ghrelin, Nesfatin, NPY and APC.
Recommended Dilution
Human: 4X / Mouse: 2X / Rat: 2X
Introduction
Angiotensin, a key player in the renin-angiotensin system, is a peptide hormone that causes vasoconstriction, increased blood pressure, and release of aldosterone from the adrenal cortex. It is derived from the precursor molecule angiotensinogen produced in the liver.Angiotensin II is formed from Angiotensin I, which is removed of two terminal residues by the enzyme Angiotensin-converting enzyme (ACE). Angiotensin II acts as an endocrine, autocrine/ paracrine, and intracrine hormone. Angiotensin II is degraded to angiotensin III by angiotensinases that are located in red blood cells and the vascular beds of most tissues. It has a half-life in circulation of around 30 seconds, while in tissue, it may be as long as 15-30 minutes.The effect of obesity on Angiotensin II has recently been reported. Obese patients show heightened renal vasodilation to blockade of the renin-angiotensin system, suggesting deficits in vascular responses to angiotensin II. This may due to increased reactivity of renal vasoconstriction to ANG II. Angiotensin II has been associated with a number of important physiological processes in heart, brain, adrenal gland and kidney. For cardiovascular effect, Angiotensin II is a potent direct vasoconstrictor, constricting arteries and veins and increasing blood pressure. It is also the most important Gq stimulator of the heart during hypertrophy. For neural effects, Angiotensin II increases thirst sensation (dipsogen) through the subfornical organ (SFO) of the brain, decreases the response of the baroreceptor reflex, and increases the desire for salt. It increases secretion of ADH in the posterior pituitary and secretion of ACTH in the anterior pituitary. For adrenal effects, Angiotensin II acts on the adrenal cortex, causing it to release aldosterone. For renal effects, Angiotensin II has a direct effect on the proximal tubules to increase Na+ absorption.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 1 Plate Kit
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?